3KF2312-0LF11
SW.DISCON. W.F. 3-P 125A/SZ.00

From SIEMENS

Switch disconnector with fuse 125 A, Size 2, 3-pole for LV HRC fuse Sz. 000 and 00 Front operating mechanism left Basic unit without handle flat terminal
Model
Product brand nameSENTRON
Product designationSwitching device
Design of the product3KF switch disconnector with fuses
Design of the operating mechanismwithout
Design of handleWithout
Direction of actuationfrom the front
Type of the driving mechanism / motor driveNo
Number of poles3
Size of disconnecting link00 and 000
Size of switch disconnector2
Size of fuse linkNH000, NH00
Electrical endurance (switching cycles)
at AC-23 A / at 440 V / at 50/60 Hz8 000
at AC-23 A / at 690 V / at 50/60 Hz5 000
at DC-23 A / at 440 V1 000
I2t value
with closed switch / for combination switch + fuse / at 500 V / maximum150 600 A²·s
with closed switch / for combination switch + fuse / at 400 V / maximum150 600 A²·s
with closed switch / at 690 V / for combination switch + gG fuse / maximum89 640 A²·s
of the fuse / at 500 V / maximum permissible223 000 A²·s
of the gG fuse / at 690 V / maximum permissible360 000 A²·s
of the aM fuse / at 690 V / maximum permissible565 000 A²·s
Mechanical service life (switching cycles) / typical12 000
Position / of the switch operating mechanismat the left end
Fuse systemLV HRC fuse
Overvoltage categoryIV
Operating voltage / with current paths in series
with degree of pollution 2 / at DC / rated value / Note440 / 3
with degree of pollution 3 / at DC / rated value / Note440 / 3
Insulation voltage / rated value1 000 V
Surge voltage resistance / rated value12 kV
Overvoltage in percent / relative to the operating voltage / at AC / at 50/60 Hz10 %
Protection class
Protection class IPIP00
Protection class IP
with closed switch / with cover or cable lug coverIP20
on the frontIP00
Dissipation
Power loss [W]
with conventional rated thermal current / per pole4.2 W
with conventional rated thermal current / per device12.6 W
with conventional rated thermal current / without fuse / per pole4.2 W
with conventional rated thermal current / without fuse / per device12.6 W
for rated value of the current / at AC / in hot operating state / per pole4.2 W
of the fuse / per fuse / maximum11 W
Operating current
at AC-21 A / at 400 V / maximum125 A
at AC-21 A / at 500 V / maximum125 A
at AC-21 A / at 690 V / maximum125 A
at AC-23 A / at 500 V / at 50/60 Hz / rated value / maximum125 A
at AC-22 A / at 500 V / at 50/60 Hz / rated value / maximum125 A
at AC-22 A / at 400 V / at 50/60 Hz / rated value / maximum125 A
at AC-22 A / at 690 V / at 50/60 Hz / rated value / maximum125 A
at AC-23 A / at 400 V / at 50/60 Hz / rated value / maximum125 A
at AC-23 A / at 690 V / at 50/60 Hz / rated value / maximum125 A
at DC-23 A / at 440 V / rated value / maximum125 A
at DC-23 A / at 220 V / rated value / maximum125 A
at DC-22 A / at 440 V / rated value / maximum125 A
at DC-22 A / at 220 V / rated value / maximum125 A
at DC-21 A / at 440 V / rated value / maximum125 A
at DC-21 A / at 220 V / maximum125 A
Continuous current
rated value125 A
at 40 °C / rated value125 A
at 45 °C / rated value125 A
at 50 °C / rated value125 A
at 55 °C / rated value125 A
at 60 °C / rated value125 A
at 65 °C / rated value125 A
at 70 °C / rated value125 A
Continuous current / at DC / rated value125 A
Let-through current / of the fuse / at 500 V / maximum permissible18 000 A
Let-through current / of the gG fuse / at 690 V / maximum permissible25 500 A
Let-through current / of the aM fuse / at 690 V / maximum permissible33 200 A
Let-through current / with closed switch
at 690 V / for combination switch + aM fuse / maximum permissible27 300 A
at 690 V / for combination switch + gG fuse / maximum permissible16 870 A
for combination switch + fuse / at 400 V / maximum permissible18 200 A
for combination switch + fuse / at 500 V / maximum permissible18 200 A
Short-time current resistance (Icw) / at 690 V AC/440 V DC / limited to 1 s / rated value5 kA
Main circuit
Operating power / at AC-23 A
at 400 V / at 50/60 Hz / rated value55 kW
at 500 V / at 50/60 Hz / rated value75 kW
at 690 V / at 50/60 Hz / rated value110 kW
Operating voltage
at AC / at 50/60 Hz / rated value690 V
at AC / rated value / maximum690 V
Auxiliary circuit
Number of connected NC contacts / for auxiliary contacts0
Number of connected NO contacts / for auxiliary contacts0
Number of connected CO contacts / for auxiliary contacts0
Number of CO contacts / for auxiliary contacts0
Number of NC contacts / for auxiliary contacts6
Number of NO contacts / for auxiliary contacts6
Suitability for use
Main switchYes
switch disconnectorYes
EMERGENCY OFF switchYes
safety switchYes
maintenance/repair switchYes
Product feature / interlockNo
Product component
Phase failure monitoringNo
Voltage triggerNo
undervoltage releaseNo
undervoltage release with leading contactNo
Product feature / sealableYes
Product extension
Auxiliary switchYes
optional
— locking capabilityYes
— motor driveNo
— fuse monitoringYes
Product function
fuse monitoringNo
Overvoltage protection monitoringNo
Short circuit
Short-circuit current making capacity (Icm) / for switch disconnector / at 690 V AC/440 V DC / without fuse link / rated value / minimum7.65 kA
Connections
Arrangement of electrical connectors / for main current circuitTop and bottom
Tightening torque / with screw-type terminals
minimum15 N·m
maximum22 N·m
Type of connectable conductor cross-sections / for aluminum conductor / stranded / with lug1x (2.5 ... 95 mm²), 2x (2.5 ... 50 mm²)
Type of connectable conductor cross-sections / for copper conductor / stranded / with lug / acc. to DIN 462341x (2.5 ... 95 mm²), 2x (2.5 ... 50 mm²)
Type of connectable conductor cross-sections / for copper conductor / stranded / with lug / acc. to DIN 462351x (25 ... 70 mm²), 2x (25 ... 50 mm²)
Type of electrical connection
for main current circuitflat connector
Mechanical Design
Height150 mm
Width190 mm
Depth161.5 mm
Mounting positionany
Mounting typefloor mounting
Mounting type
front mounting with 4-hole attachmentNo
front mounting with central attachmentNo
rail mountingNo
Net weight2 200 g
Environmental conditions
Degree of pollution3
Ambient temperature
during operation / minimum-25 °C
during operation / maximum70 °C
during storage / minimum-50 °C
during storage / maximum80 °C