3NP1133-1CA12
fuse switch disconnector 3NP1

From SIEMENS

SENTRON, Fuse switch disconnector 3NP1, 3-pole, NH00, 160 A, for assembly and installation on mounting plate, flat terminal, Fuse monitoring: electronic EFM10, Cover level 45 mm
Model
Product brand nameSENTRON
Product designation3NP1 fuse switch disconnector
Design of the productcover level 45 mm
Version of fuse monitoringelectronic EFM 10
Design of the operating mechanismCover handle
Design of the load switch / Strip formNo
Type of the driving mechanism / motor driveNo
General technical data
Number of poles3
Type of deviceFor assembly and installation on mounting plate
Size of disconnecting link00 and 000
Size of fuse linkNH000, NH00
Continuous current / at 35 °C / rated value160 A
Let-through current / with closed switch / maximum permissible23 kA
cut-off value I**2t,max. / 500 V223 000 A²·s
Power factor
at AC-22 B0.65
at AC-23 B0.45
with capacitive load-0.25
circuit-breaker / Design3NP11
Mechanical service life (switching cycles) / typical2 000
Fuse systemLV HRC fuse
Voltage
Insulation voltage / rated value690 V
Power factor / at AC-21 B0.95
Surge voltage resistance / rated value8 kV
Protection class
Protection class IP
with closed switch / with cover or cable lug coverIP40
with closed switch / without cover or cable lug coverIP30
on the frontIP40
openIP20
Dissipation
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole17 W
Electricity
Continuous current
rated value160 A
at 40 °C / rated value155 A
at 45 °C / rated value145 A
at 50 °C / rated value140 A
at 55 °C / rated value133 A
Let-through current / with high-speed activation / maximum permissible15 kA
Let-through current / Ic / maximum permissible
400 V23 000 A
500V23 000 A
cut-off value I**2t,max. / 400 V158 000 A²·s
Main circuit
Operating voltage
at AC / rated value / minimum230 V
at AC / rated value / maximum690 V
Operating current / with capacitive load
at 400 V / maximum72 A
at 500 V / maximum55 A
Auxiliary circuit
Number of CO contacts / for auxiliary contacts0
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Suitability
Suitability for use
Main switchNo
switch disconnectorYes
EMERGENCY OFF switchNo
safety switchYes
maintenance/repair switchYes
Product details
Product feature / interlockYes
Product component
Trip indicatorYes
Phase failure monitoringNo
undervoltage releaseNo
undervoltage release with leading contactNo
Product feature / sealableYes
Product extension
Auxiliary switchYes
optional
— locking capabilityYes
— motor driveNo
— Phase failure monitoringYes
— Voltage triggerNo
— Overvoltage protection monitoringYes
Product function
Product function
fuse monitoringYes
Overvoltage protection monitoringNo
Short circuit
Conditional short-circuit current (Iq)
rated value80 kA
at AC / at 500 V / with high-speed activation / rated value80 kA
at AC / at 690 V / with high-speed activation / rated value50 kA
with closed switch / at AC / at 500 V / rated value120 kA
with closed switch / at AC / at 690 V / rated value100 kA
Connections
Arrangement of electrical connectors / for main current circuitother
Connectable conductor cross-section / for main contacts
single or multi-stranded / minimum2.5 mm²
single or multi-stranded / maximum95 mm²
stranded / minimum2.5 mm²
stranded / maximum95 mm²
Tightening torque / with screw-type terminals
minimum10 N·m
maximum12 N·m
Type of electrical connection / for main current circuitbusbar connection
Mechanical Design
Height202 mm
Width105.8 mm
Depth126.2 mm
Mounting positionhorizontal/vertical
Mounting typemounting plate
Mounting type
floor mountingYes
front mountingNo
front mounting with 4-hole attachmentNo
front mounting with central attachmentNo
rail mountingNo
Net weight0.87 kg
Environmental conditions
Degree of pollution2
Ambient temperature
during operation / minimum-25 °C
during operation / maximum55 °C
during storage / minimum-50 °C
during storage / maximum80 °C

External links