3SU1400-1LK10-1AA1
PROFINET - standard interface modul

From SIEMENS

SIRIUS ACT with PROFINET: Standard interface module 24V DC, screw terminal, Front plate mounting 1 to 20 terminal modules connectable
Product brand nameSIRIUS ACT
Product designationInterface module
Product type designation3SU1
Display
Display version
for diagnostic function: Supply voltage monitoring Power LEDYes
status Tx/Rx linkYes
General technical data
Product function
Reverse polarity protectionYes
Diagnostics functionYes
AlarmsYes
I&M dataYes; I&M0 ... I&M3
Firmware version1.0.0
Hardware version1
Configuration function with datasetYes
Software version with STEP 7 in the TIA Portal requiredIntegrated in TIA Portal Version 14 SP1 or higher (HSP for V13 and V14)
Number of units per rack maximum20
Number of submodules per station maximum24
Power loss [W] typical0.67 W
Insulation voltage rated value30 V
Degree of pollution3
Type of voltage
of the operating voltageDC
of the input voltageDC
Surge voltage resistance rated value0.8 kV
Consumed current
maximum100 mA
Rated value28 mA
Protection class IPIP20
Reference code acc. to DIN EN 81346-2K
Operating voltage rated value20.4 V
I2t value0.008 A²·s
Supply voltage
Supply voltage at DC Rated value24 V
Communication/ Protocol
Product function at the Ethernet interface
AutocrossoverYes
AutonegotiationYes
Protocol at the 1st interface
media redundancy protocolNo
Product function at the 1st interface
PROFINET IO deviceYes
Product function of the PROFINET IO device is supported PROFINET system redundancy (S2)No
Service as PROFINET IO device
prioritized startupNo
isochronous modeNo
supports Shared DeviceNo
supports PROFIenergyNo
IRTNo
MRPNo
MRPDNo
Service for open IE communication
LLDPYes
SNMPYes
TCP/IPYes
GSD version/revision with PROFINET requiredV2.3
Transmission mode for Industrial EthernetPROFINET with 100 Mbps full duplex (100BASE-TX)
Network load class acc. to PROFINET1
Specification for Security Level 1 test acc. to PROFINETResilient to network loading
Control circuit/ Control
Inrush current maximum16 A
Galvanic isolation
Galvanic isolation between PROFINET and all other circuitsYes
Inputs/ Outputs
Number of digital inputs0
safety-related0
Number of digital outputs0
Connections/Terminals
Type of electrical connectionscrew-type terminals
Connectable conductor cross-section for auxiliary contacts
single or multi-stranded0.2 ... 2.5 mm²
finely stranded with core end processing2.5 mm²
Connectable conductor cross-section
solid0.2 ... 2.5 mm²
solid with core end processing0.2 ... 2.5 mm²
finely stranded with core end processing0.25 ... 2.5 mm²
finely stranded without core end processing0.2 ... 2.5 mm²
AWG number as coded connectable conductor cross section30 ... 12
Tightening torque with screw-type terminals0.5 ... 0.6 N·m
Safety related data
Service life maximum20 y
Design of the interface
Ethernet interfaceYes; for Ethernet services
Fast Ethernet interfaceYes; PROFINET with 100 Mbps
Interface design 1
integrated switchNo
RJ45 (Ethernet)Yes
Number of ports at the 1st interface1
Number of interfaces acc. to PROFINET1
Ambient conditions
Ambient temperature
during operation-25 ... +60 °C
during storage-40 ... +80 °C
Environmental category during operation acc. to IEC 607213M6, 3S2, 3B2, 3K6 (with relative air humidity of 10 ... 95 %, no condensation in operation permitted)
Explosion protection marking for intrinsic safety of related equipment EEx iaNo
Explosion protection marking for intrinsic safety of related equipment EEx ibNo
Installation/ mounting/ dimensions
Mounting type of modules and accessoriesSnap-on mounting
Height80.1 mm
Width40 mm
Depth72.1 mm

External links