6AG1131-4BD01-7AB0
SIPLUS ET200S EM 4 DI high features

From SIEMENS

SIPLUS ET 200S EM 4DI HF -25...+70°C based on 6ES7131-4BD01-0AB0 5 units per packing unit
Supply voltage
Rated value (DC)
24 V DCYes; From power module
Reverse polarity protectionYes
Input current
from supply voltage L+, max.Dependent on encoder
from backplane bus 3.3 V DC, max.10 mA
Encoder supply
Type of output voltagemin. L+ (-0.5 V), under load
Short-circuit protectionYes; Electronic
Output current
Rated value500 mA
permissible range, lower limit0 mA
permissible range, upper limit500 mA
Power loss
Power loss, typ.0.7 W
Address area
Address space per module
Address space per module, max.1 byte
with packing4 bit
Digital inputs
Number of digital inputs4
Input characteristic curve in accordance with IEC 61131, type 1Yes
Input voltage
Type of input voltageDC
Rated value (DC)24 V
for signal "0"-30 to +5V
for signal "1"+11 to +30V
Input current
for signal "1", typ.8 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizableYes; 0.1 / 0.5 / 3 / 15 ms
— at "0" to "1", min.0.05 / 0.4 / 2.7 / 14.85
— at "0" to "1", max.0,15 / 0,6 / 3,3 / 15,15
— at "1" to "0", min.0.05 / 0.4 / 2.7 / 14.85
— at "1" to "0", max.0,15 / 0,6 / 3,3 / 15,15
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Encoder
Connectable encoders
2-wire sensorYes
— permissible quiescent current (2-wire sensor), max.1.5 mA
Interrupts/diagnostics/status information
Diagnostics functionYes
Diagnostic messages
Short-circuitYes; Short-circuit of outputs to ground; module by module
Diagnostics indication LED
Group error SF (red)Yes
Status indicator digital input (green)Yes; per channel
Parameter
Remark3 byte
Diagnostics short-circuitDisable / enable
Potential separation
Potential separation digital inputs
between the channelsNo
between the channels and backplane busYes
Permissible potential difference
between different circuits75 V DC/60 V AC
Isolation
Isolation tested with500 V DC
Standards, approvals, certificates
CE markYes
Ambient conditions
Ambient temperature during operation
min.-25 °C; = Tmin
max.70 °C; = Tmax
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
Remark
— Note regarding classification of environmental conditions acc. to EN 60721* The supplied plug covers must remain in place over the unused interfaces during operation!
Dimensions
Width15 mm
Height81 mm
Depth52 mm
Weights
Weight, approx.35 g
last modified:03/13/2019