6AG1412-2EK06-2AB0
SIPLUS S7-400 CPU 412-2 PN

From SIEMENS

***SPARE PART*** ***Spare part*** SIPLUS S7-400 CPU 412-2 PN -25...+70°C with conformal coating based on 6ES7412-2EK06-0AB0. Central processing unit with: Work memory 1 MB, (0.5 MB code, 0.5 MB data) , Interfaces 1st interface MPI/DP 12 Mbit/s (X1), 2nd interface Ethernet/ PROFINET (X5). not permitted for safety-oriented applications!
General information
Product type designationCPU 412-2 PN
HW functional status01
Firmware versionV6.0
Engineering with
Programming packageSTEP 7 V5.5 or higher/iMap V3.0 + iMap STEP 7 Add-on V3.0 SP5 or higher
CiR – Configuration in RUN
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O byte30 µs; Time per I/O byte
Supply voltage
Rated value (DC)
24 V DCNo; Power supply via system power supply
Input current
from backplane bus 5 V DC, typ.1.1 A
from backplane bus 5 V DC, max.1.3 A
from backplane bus 24 V DC, max.150 mA; 150 mA per DP interface
from interface 5 V DC, max.90 mA; At the DP interface
Power loss
Power loss, typ.5.5 W
Power loss, max.6.5 W
Memory
Type of memoryRAM
Work memory
integrated1 Mbyte
integrated (for program)0.5 Mbyte
integrated (for data)0.5 Mbyte
expandableNo
Load memory
expandable FEPROMYes; with Memory Card (FLASH)
expandable FEPROM, max.64 Mbyte
integrated RAM, max.512 kbyte
expandable RAMYes; with Memory Card (RAM)
expandable RAM, max.64 Mbyte
Backup
presentYes
with batteryYes; all data
without batteryNo
Battery
Backup battery
Backup current, typ.125 µA; up to 40 °C
Backup current, max.450 µA
Backup time, max.Dealt with in the module data manual with the secondary conditions and the factors of influence
Feeding of external backup voltage to CPU5 V DC to 15 V DC
CPU processing times
for bit operations, typ.75 ns
for word operations, typ.75 ns
for fixed point arithmetic, typ.75 ns
for floating point arithmetic, typ.225 ns
CPU-blocks
DB
Number, max.3 000; Number range: 1 to 16000
Size, max.64 kbyte
FB
Number, max.1 500; Number range: 0 to 7999
Size, max.64 kbyte
FC
Number, max.1 500; Number range: 0 to 7999
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs2; OB 10, 11
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs2; OB 32, 35 (shortest cycle that can be set = 500 µs)
Number of process alarm OBs2; OB 40, 41
Number of DPV1 alarm OBs3; OB 55-57
Number of isochronous mode OBs2; OB 61-62
Number of multicomputing OBs1; OB 60
Number of background OBs1; OB 90
Number of startup OBs3; OB 100-102
Number of asynchronous error OBs9; OB 80-88
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class24
additional within an error OB1
Counters, timers and their retentivity
S7 counter
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number2 048
Retentivity
— adjustableYes
— lower limit0
— upper limit2 047
— presetNo times retentive
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in totalTotal working and load memory (with backup battery)
Flag
Number, max.4 kbyte; Size of bit memory address area
Retentivity availableYes
Retentivity presetMB 0 to MB 15
Number of clock memories8; in 1 memory byte
Local data
adjustable, max.8 kbyte
preset4 kbyte
Address area
I/O address area
Inputs4 kbyte
Outputs4 kbyte
Process image
Inputs, adjustable4 kbyte
Outputs, adjustable4 kbyte
Inputs, default128 kbyte
Outputs, default128 kbyte
consistent data, max.244 byte
Access to consistent data in process imageYes
Subprocess images
Number of subprocess images, max.15
Digital channels
Inputs32 768
— of which central32 768
Outputs32 768
— of which central32 768
Analog channels
Inputs2 048
— of which central2 048
Outputs2 048
— of which central2 048
Hardware configuration
Integrated power supplyNo
Number of expansion units, max.21
connectable OPs47
MulticomputingYes; 4 CPUs max. (with UR1 or UR2)
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.4; IM 463-2
Number of DP masters
integrated1
via CP10; CP 443-5 Extended
via IM 4674
Mixed mode IM + CP permittedNo; IM 467 not suitable for use with CP 443-5 Ext. and CP 443-1 EX4x, EX20, GX20 (in PROFINET IO mode)
via interface module0
Number of pluggable S5 modules (via adapter capsule in central device), max.6
Number of IO Controllers
integrated1
via CP4; No mixed operation of CP443-1 EX40 and CP443-1 EX 41/EX20/GX20, max. 4 in central controller
Number of operable FMs and CPs (recommended)
FMLimited by number of slots and number of connections
CP, PtPCP 440: Limited by number of slots; CP 441: Limited by number of slots and number of connections
PROFIBUS and Ethernet CPs14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller
Slots
required slots1
Time of day
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Resolution1 ms
Deviation per day (buffered), max.1.7 s; Power off
Deviation per day (unbuffered), max.8.6 s; For power On
Operating hours counter
Number16
Number/Number range0 to 15
Range of valuesSFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours
Granularity1 h
retentiveYes
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
on Ethernet via NTPYes; As client
Time difference in system when synchronizing via
Ethernet, max.10 ms
MPI, max.200 ms
Interfaces
Interfaces/bus type1 x MPI/PROFIBUS DP, 1 x PROFINET (2 ports)
Number of RS 485 interfaces0
Number of other interfaces0
1. Interface
Interface typeIntegrated
PhysicsRS 485 / PROFIBUS + MPI
IsolatedYes
Power supply to interface (15 to 30 V DC), max.150 mA
Number of connection resourcesMPI: 32, DP: 16
Protocols
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP slaveYes
MPI
Number of connections32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
Transmission rate, max.12 Mbit/s
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
PROFIBUS DP master
Number of connections, max.16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32
Services
— PG/OP communicationYes
— RoutingYes
— Global data communicationNo
— S7 basic communicationYes
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— EquidistanceYes
— Isochronous modeYes
— SYNC/FREEZEYes
— Activation/deactivation of DP slavesYes
— Direct data exchange (slave-to-slave communication)Yes
— DPV1Yes
Address area
— Inputs, max.2 kbyte
— Outputs, max.2 kbyte
User data per DP slave
— User data per DP slave, max.244 byte
— Inputs, max.244 byte
— Outputs, max.244 byte
— Slots, max.244
— per slot, max.128 byte
PROFIBUS DP slave
Number of connections16
GSD file
Transmission rate, max.12 Mbit/s
automatic baud rate searchNo
Address area, max.32; Virtual slots
User data per address area, max.32 byte
— of which consistent, max.32 byte
Services
— PG/OP communicationYes; with interface active
— S7 routingYes; with interface active
— Global data communicationNo
— S7 basic communicationNo
— S7 communicationYes
— S7 communication, as clientYes
— S7 communication, as serverYes
— Direct data exchange (slave-to-slave communication)No
— DPV1No
Transfer memory
— Inputs244 byte
— Outputs244 byte
2. Interface
Interface typePROFINET
PhysicsEthernet RJ45
IsolatedYes
automatic detection of transmission rateYes; Autosensing
AutonegotiationYes
AutocrossingYes
Change of IP address at runtime, supportedYes; Assignment by higher-level IO-Controller or by the user program with SFB104 "IP_CONF"
Number of connection resources48
Interface types
Number of ports2
integrated switchYes
Media redundancy
supportedYes
Switchover time on line break, typ.200 ms
Number of stations in the ring, max.50
Protocols
PROFINET IO ControllerYes
PROFINET IO DeviceYes
PROFINET CBAYes
PROFIBUS DP masterNo
PROFIBUS DP slaveNo
Open IE communicationYes
Web serverYes
Point-to-point connectionNo
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes
— S7 routingYes
— S7 communicationYes
— Isochronous modeYes; Only with IRT and the High Performance option
— Open IE communicationYes
— Shared deviceYes
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.32
— Number of connectable IO Devices, max.256
— Of which IO devices with IRT, max.64
— of which in line, max.64
— Number of IO Devices with IRT and the option "high flexibility"256
— of which in line, max.61
— Number of connectable IO Devices for RT, max.256
— of which in line, max.256
— Activation/deactivation of IO DevicesYes
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8; 8 parallel calls of the SFC 12 "D_ACT_DP" possible per line. Max. 32 IO Devices changing during operation (partner ports) are supported
— Device replacement without swap mediumYes
— Send cycles250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame
— Updating time250 µs to 512 ms; minimum value depends on preset communication share for PROFINET IO, on the number of IO Devices and on the amount of configured user data, see PROFINET system description
Address area
— Inputs, max.4 kbyte
— Outputs, max.4 kbyte
— User data consistency, max.1 024 byte
PROFINET IO Device
Services
— PG/OP communicationYes
— S7 routingYes
— S7 communicationYes
— Isochronous modeNo
— Open IE communicationYes
— IRTYes
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.2
Transfer memory
— Inputs, max.1 440 byte; Per IO Controller with shared device
— Outputs, max.1 440 byte; Per IO Controller with shared device
Submodules
— Number, max.64
— User data per submodule, max.1 024 byte
PROFINET CBA
acyclic transmissionYes
cyclic transmissionYes
Open IE communication
Number of connections, max.46
Local port numbers used at the system end0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Keep-alive function, supportedYes
Protocols
Open IE communication
TCP/IPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.46
— Data length, max.32 kbyte
— several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes; Via integrated PROFINET interface or CP 443-1 Adv. and loadable FBs
— Number of connections, max.46
— Data length, max.32 kbyte; 1452 bytes via CP 443-1 Adv.
UDPYes; via integrated PROFINET interface and loadable FBs
— Number of connections, max.46
— Data length, max.1 472 byte
Web server
supportedYes
User-defined websitesYes
Number of HTTP clients5
Isochronous mode
Isochronous operation (application synchronized up to terminal)Yes; Via PROFIBUS DP or PROFINET interface
EquidistanceYes
Number of DP masters with isochronous mode1
User data per isochronous slave, max.244 byte
shortest clock pulse1.5 ms; 0.5 ms without use of SFC 126, 127
max. cycle32 ms
Communication functions
PG/OP communicationYes
Number of connectable OPs without message processing47
Number of connectable OPs with message processing47; When using Alarm_S/SQ and Alarm_D/DQ
Data record routingYes
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.16
Size of GD packets, max.54 byte
Size of GD packet (of which consistent), max.1 variable
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.1 variable
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 kbyte
User data per job (of which consistent), max.462 byte; 1 variable
S5 compatible communication
supportedYes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5
User data per job, max.8 kbyte
User data per job (of which consistent), max.240 byte
Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.24/24
Standard communication (FMS)
supportedYes; Via CP and loadable FB
PROFINET CBA (at set setpoint communication load)
Setpoint for the CPU communication load20 %
Number of remote interconnection partners32
Number of functions, master/slave150
Total of all master/slave connections4 500
Data length of all incoming connections master/slave, max.45 000 byte
Data length of all outgoing connections master/slave, max.45 000 byte
Number of device-internal and PROFIBUS interconnections1 000
Data length of device-internal und PROFIBUS interconnections, max.16 000 byte
Data length per connection, max.2 000 byte
Remote interconnections with acyclic transmission
— Sampling frequency: Sampling time, min.200 ms; Depending on preset communication load, number of interconnections and data length used
— Number of incoming interconnections250
— Number of outgoing interconnections250
— Data length of all incoming interconnections, max.8 000 byte
— Data length of all outgoing interconnections, max.8 000 byte
— Data length per connection, max.2 000 byte
Remote interconnections with cyclic transmission
— Transmission frequency: Transmission interval, min.1 ms; Depending on preset communication load, number of interconnections and data length used
— Number of incoming interconnections300
— Number of outgoing interconnections300
— Data length of all incoming interconnections, max.4 800 byte
— Data length of all outgoing interconnections, max.4 800 byte
— Data length per connection, max.450 byte
HMI variables via PROFINET (acyclic)
— Number of stations that can log on for HMI variables (PN OPC/iMap)2x PN OPC/1x iMap
— HMI variable updating500 ms
— Number of HMI variables1 000
— Data length of all HMI variables, max.32 000 byte
PROFIBUS proxy functionality
— supportedYes; 32 PROFIBUS slaves max. connectable
— Data length per connection, max.240 byte; Slave-dependent
Number of connections
overall48
usable for PG communication
— reserved for PG communication1
— adjustable for PG communication, max.0
usable for OP communication
— reserved for OP communication1
— adjustable for OP communication, max.0
usable for S7 basic communication
— reserved for S7 basic communication0
— adjustable for S7 basic communication, max.0
usable for S7 communication
— reserved for S7 communication0
— adjustable for S7 communication, max.0
usable for routing
— reserved for routing0
— adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC)
Symbol-related messagesYes
SCAN procedureYes
Program alarmsYes
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks
Alarm 8-blocksYes
Number of instances for alarm 8 and S7 communication blocks, max.300
preset, max.150
Process control messagesYes
Number of archives that can log on simultaneously (SFB 37 AR_SEND)4
Number of messages
overall, max.256
in 100 ms grid, max.0
in 500 ms grid, max.256
in 1000 ms grid, max.256
Number of additional values
with 100 ms grid, max.0
with 500, 1000 ms grid, max.1
Test commissioning functions
Status blockYes; Up to 16 simultaneously
Single stepYes
Number of breakpoints16
Status/control
Status/control variableYes; Up to 16 variable tables
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.70; Status/control
Forcing
ForcingYes
Forcing, variablesInputs/outputs, bit memories, distributed I/Os
Number of variables, max.64
Diagnostic buffer
presentYes
Number of entries, max.400
— adjustableYes
— preset120
Service data
can be read outYes
EMC
Emission of radio interference acc. to EN 55 011
Limit class A, for use in industrial areasYes
Limit class B, for use in residential areasNo
Standards, approvals, certificates
CE markYes
Ambient conditions
Ambient temperature during operation
min.-25 °C; = Tmin
max.70 °C; = Tmax; @ 60°C for UL/ATEX/FM use
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres!
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
Configuration
Configuration software
STEP 7Yes
Programming
Command setsee instruction list
Nesting levels7
Access to consistent data in process imageYes
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Number of simultaneously active SFCs
— DPSYC_FR2
— D_ACT_DP8
— RD_REC8
— WR_REC8
— WR_PARM8
— PARM_MOD1
— WR_DPARM2
— DPNRM_DG8
— RDSYSST8
— DP_TOPOL1
Number of simultaneously active SFBs
— RDREC8
— WRREC8
Know-how protection
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions
Width25 mm
Height290 mm
Depth219 mm
Weights
Weight, approx.750 g
last modified:03/25/2019