6AU1410-0AB00-0AA0
SIMOTION D410 PN

From SIEMENS

***SPARE PART*** SIMOTION DRIVE-BASED CONTROL UNIT D410 PN; PROGRAMMABLE SINGLE-AXIS MOTION CONTROLLER; INTERFACES: 4 DI, 4 DI/DO, 1 EP, 1 TEMP, 1 ENCODER, 1 DRIVE-CLIQ, 2 PROFINET PORTS
Article number6AU1410-0AB00-0AA0
Product brand nameSIMOTION
Product type designationD410 PN
Version of the motion control systemSingle-axis system
PLC and motion control performance
Number of axes / maximum1
Maximum number of axes / noteThe value indicated refers to real axes; virtual axes can be used additionally.
Minimum PROFINET send cycle clock0.5 ms
Minimum interpolator cycle clock2 ms
Minimum servo cycle clock2 ms
Integrated drive control
Maximum number of axes for integrated drive control
servo1
vector1
V/f1
noteAlternative control modes; drive control based on SINAMICS S120 CU310, firmware version V2.x
Memory
RAM (work memory)38 Mbyte
Additional RAM work memory for Java applications20 Mbyte
RAM disk (load memory)23 Mbyte
Retentive memory9 kbyte
Persistent memory (user data on CF)300 Mbyte
Communication
Interfaces
DRIVE-CLiQ1
PROFINET1
— note1 interface with 2 ports: - supports PROFINET IO with IRT and RT - can be configured as PROFINET IO controller and/or device
General technical data
FanIntegrated
DC supply voltage
rated value24 V
minimum20.4 V
maximum28.8 V
Consumed current / typical800 mA
Notewith no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ interface
Making current, typ.3 A
Power loss [W] / typical20 W
Ambient temperature, during
storage-40 ... +70 °C
transport-40 ... +70 °C
operation0 ... 55 °C
— noteMaximum 5000 m (16405 ft) above sea level. Above an altitude of 2000 m (6562 ft), the max. ambient temperature decreases by 7 °C (12.6 °F) every 1000 m (3281 ft).
Relative humidity
during operation5 ... 95 %
without condensation, tested acc. to IEC 60068-2-38Wert fehlt
Air pressure700 ... 1 060 hPa
Degree of protectionIP20
Height183.2 mm
Width73 mm
Depth89.6 mm
Net weight990 g
Digital inputs
Number of digital inputs4
DC input voltage
rated value24 V
for signal "1"15 ... 30 V
for signal "0"-3 ... +5 V
Electrical isolationYes
noteYes, in groups of 4
Current consumption for "1" signal level, typ.10 mA
Input delay time for
signal "0" → "1", typ.50 µs
signal "1" → "0", typ.150 µs
Digital inputs/outputs
Number of digital I/Os4
Parameterization possibility of the digital I/Osparameterizable as DI, as DO, as measuring input input (max. 3), as output of output cam (max. 4)
If used as an input
DC input voltage
rated value24 V
for signal "1"15 ... 30 V
for signal "0"-3 ... +5 V
Electrical isolationNo
Current consumption for "1" signal level, typ.10 mA
Input delay time for DI 9 to DI 11 for
signal "0" → "1", typ.5 µs
signal "1" → "0", typ.50 µs
— notecan also be used as probe inputs
Input delay time for DI 8 for
signal "0" → "1", typ.50 µs
signal "1" → "0", typ.100 µs
Measuring input / reproducibility5 µs
If used as an output
Load voltage
rated value24 V
minimum20.4 V
maximum28.8 V
Electrical isolationNo
Current carrying capacity for each output, max.500 mA
Leakage current, max.2 mA
Output delay for
signal "0" → "1", typ.150 µs
signal "0" → "1", max.400 µs
signal "1" → "0", typ.75 µs
signal "1" → "0", max.100 µs
— noteData for Vcc = 24 V; load 48 Ohm; "1" = 90 % VOut, "0" = 10 % VOut
Cam output
reproducibility200 µs
— notetyp. 200 µs for 3 ms bus/servo cycle; typ. 300 µs for 6 ms bus/servo cycle
Switching frequency of the outputs for
resistive load, max.100 Hz
inductive load, max.0.5 Hz
lamp load, max.10 Hz
Short-circuit protectionYes
Onboard encoder interface
Encoder interfaceoptional incremental encoder TTL, incremental encoder HTL or absolute encoder SSI without incremental signals TTL/HTL
Encoder supply for
24 VDC0.35 A
5 VDC0.35 A
Limiting frequency, max.500 kHz
SSI baud rate100 ... 250
Resolution of absolute position SSI30 bit
Cable length for
TTL incremental encoder, max.100 m
HTL incremental encoder for
— unipolar signals, max.100 m
— bipolar signals, max.300 m
— noteTTL only bipolar signals; for bipolar signals, the signal lines must be twisted in pairs and shielded
SSI absolute encoder, max.100 m
Additional technical data
Design of the sensor / to detect the ambient temperature / connectableKTY84-130 or PTC
Back-up of non-volatile data
of retentive dataunlimited buffer duration
of real-time clock, min.5 d
noteData buffering is maintenance-free
Approvals
USAcULus
CanadacULus

External links