| SIMATIC ET 200SP HA, digital input module, DI 16XNAMUR HA, suitable for terminal block H1, M1, color code CC01, channel diagnostics |
General information |
Product type designation | DI 16xNAMUR HA |
Firmware version | V1.0 |
FW update possible | Yes |
Usable terminal block | TB type H1, M1 and N0 |
Color code for module-specific color identification plate | CC01 |
Product function |
I&M data | Yes; I&M0 to I&M3 |
Engineering with |
PCS 7 configurable/integrated as of version | V9.0 |
Operating mode |
DI | Yes |
Counter | No |
Redundancy |
Redundancy capability | Yes; With TB type M1 |
Supply voltage |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Input current |
Current consumption (rated value) | 95 mA |
Current consumption, max. | 115 mA |
Encoder supply |
Number of outputs | 16 |
Output voltage encoder supply, min. | 8.1 V |
Short-circuit protection | Yes |
Power |
Power available from the backplane bus | 74 mW |
Power loss |
Power loss, typ. | 2.4 W |
Address area |
Address space per module |
Address space per module, max. | 2 byte; + 2 bytes for QI information |
Digital inputs |
Number of digital inputs | 16; NAMUR |
Digital inputs, parameterizable | Yes |
Pulse extension | Yes; 0.5 s, 1 s, 2 s |
Time stamping | Yes |
Time stamp (with precision of 1 ms) | No |
Edge evaluation | Yes; rising edge, falling edge, edge change |
Signal change flutter | Yes; 2 to 32 signal changes |
Flutter observation window | Yes; 0.5 s, 1 s to 100 s in 1-s steps |
Input voltage |
Rated value (DC) | 8.2 V |
Input current |
for 10 k switched contact |
— for signal "0" | 0.35 to 1.2 mA |
— for signal "1" | 2.1 ... 6.4 mA |
for unswitched contact |
— for signal "0", max. (permissible quiescent current) | 0.5 mA |
— for signal "1" | typ. 8 mA |
for NAMUR encoders |
— for signal "0" | 0.35 to 1.2 mA |
— for signal "1" | 2.1 ... 6.4 mA |
Input delay (for rated value of input voltage) |
tolerated changeover time for changeover contacts | 300 ms |
for NAMUR inputs |
— at "0" to "1", max. | 17 ms |
— at "1" to "0", max. | 25 ms |
Cable length |
shielded, max. | 600 m |
unshielded, max. | 200 m |
Encoder |
Connectable encoders |
NAMUR encoder/changeover contact according to EN 60947 | Yes |
Single contact / changeover contact unconnected | Yes |
Single contact / changeover contact connected with 10 kΩ | Yes |
2-wire sensor | Yes; Acc. to NAMUR |
— permissible quiescent current (2-wire sensor), max. | 1.2 mA |
Interrupts/diagnostics/status information |
Alarms |
Diagnostic alarm | Yes; channel by channel |
Hardware interrupt | Yes; Parameterizable, channels 0 to 15, rising/falling edge |
Diagnostic messages |
Diagnostic information readable | Yes |
Monitoring the supply voltage | Yes |
— parameterizable | Yes |
Monitoring of encoder power supply | Yes |
Wire-break | Yes |
Short-circuit | Yes |
Group error | Yes |
Changeover contact error | Yes |
Diagnostics indication LED |
MAINT LED | Yes; yellow LED |
Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
Channel status display | Yes; Green LED |
for channel diagnostics | Yes; Red LED |
for module diagnostics | Yes; green/red DIAG LED |
Potential separation |
Potential separation channels |
between the channels | No |
between the channels and backplane bus | Yes |
Between the channels and load voltage L+ | Yes |
Isolation |
Isolation tested with | 1 500 V DC/1 min, type test |
Ambient conditions |
Ambient temperature during operation |
horizontal installation, min. | -40 °C |
horizontal installation, max. | 70 °C |
vertical installation, min. | -40 °C |
vertical installation, max. | 60 °C |
Dimensions |
Width | 22.5 mm |
Height | 115 mm |
Depth | 138 mm |
Weights |
Weight, approx. | 153 g |
last modified: | 03/08/2019 |