871897
Industrial Valves - Proportional; directional valve; size D08 NG25; 2-stage; feedback

From Vickers

FeatureCodeDescription
VALVE TYPEKF(KF) PROPORTIONAL VALVE WITHOUT INTEGRAL AMPLIFIER
CONTROL TYPED(D) DIRECTIONAL VALVE
MOUNTINGG(G) SUBPLATE MOUNTED
OPERATION5(5) SOLENOID CONTROLLED PILOT OPERATED
PRESSURE RATINGV(V) MAX PRESS 315 BAR FOR SIZE 5 & 350 BAR FOR SIZE 7,8 ON P, A & B
INTERFACE-8(8) ISO-4401 SIZE 08
SPOOL TYPE-2(2) P,A,B,T BLOCKED, (STANDARD FLOW PLOT)
SPRING ARRANGMENTC(C) SPRING CENTERED, DUAL SOLENOID
RATED FLOW300N(300N) 300 L/MIN (79 USGPM) WITH METER IN & METER OUT
PILOT SUPPLY-EX(EX) EXTERNAL PILOT PRESSURE WITH PRESSURE REDUCER
PILOT DRAIN_(0) EXTERNAL PILOT DRAIN
SOLENOID IDENTITY-VM(VM) SOL A IS AT PORT A AND SOL B IS AT PORT B
ELECTRICAL CONNECTION-U1(U1) ISO 4400 WITH FITTED PLUGS
COIL VOLTAGE-H(H) 24V DC
TANK PORT RATING1(1) 4 BAR MAXIMUM
DESIGN CODE-12(12) DESIGN NUMBER FOR 7 & 8 INTERFACE

External links